Why Support Spacing Matters When Selecting Aluminium Solar Purlins – 2026

Why Support Spacing Matters When Selecting Aluminium Solar Purlins

At first it may not seem so, but the distance between structural supports can have a bigger impact on solar mounting system performance. A purlin that is suitable for a relatively short span may bend or deflect too much if the distance between its supports is increased. This makes the support spacing one of the most important considerations when selecting aluminium solar purlins, especially in large-scale photovoltaic installations where the structural efficiency and material consumption directly impact the project costs.

Aluminium purlins are supporting members in solar mounting structures that transfer loads from photovoltaic modules and their connections to the underlying structural system. Based on the mounting configuration, these members must withstand forces created by module weight, wind pressure, wind uplift, snow accumulation and other project-specific loading conditions. The performance of these functions depends not only on the dimensions of the aluminium alloy or profile, but also on the frequency of support along the length.

The relationship between support spacing and purlin performance is particularly critical because bending moments and deflection do not increase linearly with span. A small increase in the distance between the supports can cause a large increase in the deformation under the same loading and support conditions. Thus a profile which satisfies structural requirements at one spacing may require a deeper cross-section, greater wall thickness or a different support arrangement when used over a longer span.

This consideration is particularly relevant when aluminium is used. Aluminium has advantages such as low weight, corrosion resistance and flexibility in profile manufacturing. However, the elastic modulus of aluminium is significantly lower than that of structural steel. Hence, stiffness and deflection requirements can be important in determining the correct aluminium purlin shape.

But that doesn’t automatically make it the most economical solution to reduce the spacing of supports. Closer supports may permit the use of smaller or lighter purlins but may also increase the number of supporting members, connections and installation operations required. A wider spacing may ease some of the structural layout but puts more demands on the individual purlins.

For utility-scale solar projects where similar components are repeated over large mounting structures, these differences can impact total aluminium consumption, fabrication requirements, transport, installation efficiency and overall project economics.

The aim is therefore not only to maximise the distance between supports or minimise the weight of each profile. The goal is to find a configuration that uses materials efficiently, while having the required strength, stiffness, stability and connection performance.

In this guide we will look at why the spacing of supports is important when considering the selection of aluminium solar purlins, how span affects bending and deflection and how the geometry of a profile, structural loading and installation requirements should be considered together. We will additionally address the relationship between support spacing and material efficiency to understand how a suitable purlin arrangement can result in strong and economical solar mounting structures.

What Is Support Spacing in Aluminium Solar Purlins?

Support spacing refers to the distance between structural points supporting an aluminium purlin in a solar mounting system. These supports may be beams, brackets, frames or other structural members that transmit loads from the purlin to the primary supporting structure.

In practice, the span length of a purlin to carry loads from photovoltaic modules will be determined by the support spacing. This distance directly influences the bending moments, deflection and structural properties required of the chosen aluminium profile.

For example, the behaviour of an aluminium purlin supported at 1,000 mm intervals will be different from the same profile supported at 1,500 mm intervals, even if the material, cross-section and loading conditions are the same. The more spaced apart the supports are, the greater the structural demands on the member . The precise relationship depends on the support conditions and loading arrangement.

This is why the Aluminium purlin span should be determined before finalising the profile dimensions or wall thickness.

Support Spacing and Purlin Span Are Closely Related

The distance between two adjacent supports in a simple structural arrangement is called the span of the purlin. However, the relationship becomes more complex when the member spans more than one support.

A simply supported purlin is a purlin that carries loads between two supports and doesn’t develop significant bending moment resistance at the supports. The bending and deflection behaviour can be assessed by the appropriate beam relationships for the applied loads.

Whereas a continuous purlin spans across several supports. The bending moments are redistributed along the member in this type of arrangement and the structure behaves differently from a series of independent simply supported spans.

Continuous layouts may be beneficial in certain designs, but they also introduce additional design considerations regarding support moments, connection behaviour and installation tolerances.

Hence, the performance of a solar purlin is not only determined by the number of supports. You have to consider the actual structural arrangement and the way the member is supported .

Support Spacing Is Not the Same as Module Spacing

Another important difference is the spacing of purlin supports compared to the spacing of PV modules.

Module spacing typically means the distance or gap between the photovoltaic modules in the array. This may be influenced by module dimensions, thermal movement requirements, clamps and installation details depending on the mounting system.

The purlin support spacing, however, is the distance between the structural supports holding the purlin.

The overall mounting system geometry relates these dimensions, but they serve different engineering purposes and are not interchangeable.

The solar mounting structure may consist of uniform module spacing but different purlin support schemes for different structural load or site conditions.

Why the Distance Between Supports Changes Structural Behaviour

An understanding of support spacing can be better gained by looking at how a purlin behaves under load.

With increasing support spacing, the member experiences more bending demand and deformation for otherwise similar loading conditions. The extent of such changes depends on whether the loads are continuously distributed, applied at individual module connection points, or transferred by some other structural arrangement.

So a profile chosen for one support configuration cannot be taken for granted to be appropriate for another.

An aluminium purlin that is strong enough for a short span may require a deeper section or a greater moment of inertia when used over a longer distance. In some situations deflection may control the design rather than material strength.

The connection between the purlin and its support is of equal importance. A connection that allows rotation is not the same as one that restricts rotation. Not assuming that a connection is rigid when it is not will result in wrong estimates of bending moments and deflection.

The support spacing, connection behaviour and profile geometry have therefore to be looked upon as parts of the same structural system.

In solar mounting projects, it is important to get the support arrangement right at the beginning of the design process to avoid engineers specifying profiles that are too heavy or too flexible.
It also allows for a more reliable assessment of material use, installation needs and the overall efficiency of the project.

The next step is to consider how changes in support spacing affect bending moments and deflection and why these relationships are particularly important when designing aluminium solar purlins.

How Support Spacing Affects Bending and Deflection

One of the key reasons to look at support spacing when choosing aluminium solar purlins is that it directly impacts bending moments and deflection. Even if the same aluminium profile and material grade are used, changing the distance between supports can have a large effect on the way the member behaves under load.

The relationship is particularly important in solar mounting structures, where purlins are required to maintain adequate strength and stiffness in supporting photovoltaic modules under varying environmental conditions. In a short span, a section may perform well, but with increased support spacing, although the applied load per metre is the same, the section may become unsuitable.

How Support Spacing Influences Bending Moments

When a purlin is loaded between two supports, internal bending moments are generated in a purlin. The size of the bending moment depends on the span, loading arrangement and support conditions.
For a simply supported purlin under a uniformly distributed load, the maximum bending moment is given by:

Mmax = wL^2 / 8

Where:

  • Mmax = maximum bending moment
  • w = uniformly distributed load per length
  • L = length between supports.

The important point now is that under these particular conditions the bending moment increases as the square of the span.

For example, increasing the support spacing from 1,000 mm to 1,200 mm is a 20% increase in span. If the distributed load is constant, the maximum bending moment increases by approximately 44%.

This means a relatively small change in the support spacing can result in a much greater demand on the aluminium purlin.

With increasing bending moments, the engineer may have to select a section with a higher bending resistance. Depending on the design this can mean increasing the profile depth, changing the cross-section geometry or selecting a different wall thickness.

But bending resistance is only one part of the equation.

Why Deflection Can Be Even More Critical

Deflection describes the displacement of a structural member under load. In solar mounting systems, excessive purlin deflection can affect the alignment of photovoltaic modules, alter the behaviour of connections and introduce deformation beyond the limits permitted by the mounting-system design.

For a simply supported beam carrying a uniformly distributed load, the maximum elastic deflection is:

δmax = 5 × w × L⁴ / (384 × E × I)

Where:

  • δmax = maximum deflection
  • w = uniformly distributed load per unit length
  • L = span between supports
  • E = modulus of elasticity
  • I = second moment of area of the cross-section

The most important part of this relationship is the term \(L^4\).

Under the stated assumptions, deflection increases with the fourth power of the span. Consequently, even relatively small increases in support spacing can produce substantial changes in deformation.

Consider the same 20% increase in span used in the previous example. With the same load per metre, material and cross-section, the calculated deflection increases by approximately 107%.

In other words, the deflection becomes slightly more than twice its original value.

This explains why a purlin that appears sufficiently strong may still require a different section when the support spacing increases.

Illustrative comparison: same section, uniform load per metre and simply supported conditions

Relative values normalized to a 1.0 m span; idealized simply supported beam under constant uniformly distributed load.

■ Relative bending moment

■ Relative deflection

These are theoretical ratios, not project-specific design results. Real solar purlins may have different support conditions and concentrated module loads.

Why Aluminium Stiffness Matters

Aluminium has several advantages for solar mounting applications: it is relatively lightweight, offers good corrosion resistance and can be manufactured into complex extruded profiles.
It has, however, a much lower elastic modulus than structural steel.

The modulus of elasticity for many widely used structural aluminium alloys is about 70 GPa, whereas for structural steel it is approximately 210 Gpa.

This results in an aluminium member deflecting elastically approximately three times as much as a steel member for the same geometry and loading conditions.

This comparison does not mean that aluminium is not suitable for solar mounting structures.

Aluminium profiles are often designed with geometries that provide the necessary stiffness and take advantage of the relatively low density of the material.

It does mean however that profile geometry and support spacing are especially important when designing aluminium solar purlins.

A deeper or better shaped aluminium profile might provide the required moment of inertia without simply increasing wall thickness all over the section.

Simply Supported and Continuous Purlins Behave Differently

The relations discussed above are for a particular structural model: a simply supported beam with a uniform distributed load.

Real solar mounting systems can act differently.

Some aluminium purlins are continuous over a number of supports; others are joined by brackets or joints with varying degrees of restraint to rotation.

The bending moments in a continuous purlin are distributed differently along the member. Negative moments occur in intermediate supports while positive moments occur in spans.

This can lead to less deflection in some areas than a simply supported arrangement but imposes greater demands near the supports.

The actual response depends on stiffness of support, span arrangement, connection behaviour and loading conditions.

Also, PV modules may apply loads to the purlins at discrete locations where they are clamped or fastened, as opposed to a perfectly uniform load.

For these reasons simplified beam equations are useful to understand the effect of support spacing but the final choice of aluminium purlin must be based on the actual structural configuration and the applicable design requirements.

Balancing Bending Resistance and Deflection

It is a common mistake in purlin selection to place emphasis on bending strength at the expense of stiffness.

It may be that the profile has sufficient bending resistance for the calculated loads, but the deformation over the chosen span is too large.

The opposite can happen as well. A member may be adequately stiff, but may need to be checked for local buckling, connection capacity or other strength related limit states.

Thus, the spacing of supports should be verified against ultimate limit state requirements (concerning the structural resistance and stability) and serviceability limit state requirements (concerning deformation and operational performance).

The most efficient aluminium purlin is not necessarily the one with the highest resistance in bending or the lowest weight. It is the section that meets the required strength, stiffness, stability, and connection conditions for a given support spacing.

This relationship leads to the next important question. How does aluminium profile geometry, section depth and wall thickness affect purlin performance and why is it sometimes more efficient to change the cross-section rather than simply adding material?

Aluminium Profile Geometry and Section Selection

Once the support spacing is established, the next step is to decide which aluminium profile can provide the required structural performance. Two purlins of the same aluminium alloy can behave very differently under same loading conditions if the geometry of their cross-section is different.

So, it can be misleading to choose aluminium solar purlins by external size, wall thickness or weight per meter. It’s not only the amount of material, but the distribution of material within the cross-section is equally important.

In solar mounting applications the goal is to identify a profile that provides adequate bending resistance and stiffness without adding additional material weight or manufacturing complexity.

Why Section Depth and Moment of Inertia Matter

This is one of the most influential properties of a purlin cross section and is usually denoted by the symbol I . This geometric property is a measure of how the material is distributed about the bending axis and is an important factor in determining the stiffness of a structural member.

As mentioned above the elastic deflection is a function of both the modulus of elasticity and the second moment of area. The material is the main factor for the elastic modulus, while the moment of inertia is highly dependent on the geometry of the profile.

Increasing the depth of the purlin in the direction of bending gives a major effect on the stiffness of the purlin. This is because material further away from the neutral axis is more effective in contributing to the second moment of area.

For example, a relatively deep aluminium extrusion may have a higher bending stiffness than a shallower section with similar area of cross-section. Where larger spans of support are required, the depth of the profile will be an important design variable.

But more depth is not always the best answer. The dimensions of the purlin can be restricted by the space available for installation, the module clearance, the fastening details and the geometry of the supporting structure.

Therefore, the most suitable profile has to find a balance between structural performance and the physical demands of the solar mounting system.

Section Modulus, Wall Thickness and Local Stability

The second moment of area is related to stiffness. The section modulus is an important parameter when considering bending stresses and resistance.

For an elastic section subjected to bending, the relationship between the bending moment and the maximum normal stress is:

Bending Stress: σ = M / W

Where σ is the bending stress, M is the applied bending moment and W is the elastic section modulus about the appropriate bending axis.

In general, a profile of higher section modulus can withstand a given bending moment at a lower elastic bending stress. Actual design resistance however also depends on the aluminium alloy, temper, cross-sectional classification and applicable structural design requirements.

Another thing is wall thickness. Increasing the thickness can improve some strength, stiffness and local stability attributes, but it also increases material usage.

Local buckling may be an important design consideration for thin walled aluminium extrusions. The overall dimensions of a section may be satisfactory, but the walls may be slender and require further checking for compression or bending.

This is particularly so for open sections or profiles with relatively slender flanges and webs.

So, increasing the total height of a profile without paying attention to wall proportions and local stability will not necessarily make the design more efficient.

The cross section must be considered as an entire structural shape.

Why Extruded Aluminium Profiles Offer Design Flexibility

One of the benefits of aluminium in solar mounting is that extrusion permits the production of profiles with relatively complex cross-sectional geometries.

This enables designers to put material where it helps structural performance and also put in features for fastening, positioning and assembly.

Depending on the mounting system, an aluminium purlin can have integrated channels, strengthened edges or connection details for assembly.

These details can improve the practical utility of a profile, but they also affect its structural behaviour.

For example, the effective cross-sectional properties may be affected by grooves and openings and the geometry around bolt connections may affect local load transfer.

Thus, the profile should be assessed with its actual cross-sectional properties and not approximated as a simple rectangular member.

Furthermore, the bending axis has to be taken into account carefully. Many aluminium profiles possess different moments of inertia about their principal axs and thus can be very different in stiffness depending on orientation.

A section which is good for bending in one direction may be less good when loads are applied in another direction or when combined bending and torsion are important.

Matching Profile Geometry to Support Spacing

The relationship between aluminium purlin span and profile geometry is central to efficient solar mounting design.

Shorter spans may allow relatively compact profiles to satisfy both strength and deflection requirements. As support spacing increases, a profile with greater bending stiffness or resistance may become necessary.

However, selecting a larger section should not be the automatic response to every increase in span.

In some cases, adjusting the support arrangement may be more efficient than increasing the dimensions of every purlin. In others, a carefully designed extrusion with a more favourable distribution of material may provide the required performance without a substantial increase in weight.

The choice also depends on the loading direction, connection arrangement and whether the purlin behaves as a simply supported or continuous member.

For utility-scale solar projects, these decisions can have a considerable cumulative effect. A relatively small reduction in aluminium weight per metre may translate into significant material savings when the same profile is used throughout an extensive mounting structure.

At the same time, reducing material without sufficient structural verification can introduce problems related to deflection, local instability or connection performance.

The goal is therefore not to select the thinnest or lightest available profile, but to identify an aluminium purlin cross-section that satisfies the required structural performance at the intended support spacing.

This requires the profile geometry, material properties, span arrangement and connection details to be considered together, with the final design verified against the loads expected throughout the service life of the solar installation.

Wind, Snow and Module Loads in Solar Purlin Design

Support spacing and profile geometry are essential considerations when selecting aluminium solar purlins, but neither can be evaluated independently of the loads acting on the structure. A purlin may have sufficient stiffness for a particular span under the weight of photovoltaic modules, yet require a different cross-section or support arrangement when wind and snow loads are considered.

In solar mounting systems, purlins form part of the load-transfer path between the PV modules and the primary supporting structure. Their performance depends on the magnitude, direction and distribution of the applied forces, as well as the way those forces are transferred through module clamps, fasteners and structural connections.

For this reason, solar purlin support spacing should always be evaluated together with the project’s structural loading conditions.

Wind Loads and Uplift Forces

Wind is one of the most important environmental actions affecting solar mounting structures. Depending on the location, terrain, module inclination and array configuration, wind can generate both downward pressure and upward suction on photovoltaic modules.

Wind uplift is particularly significant because it can reverse the direction of loading experienced by the purlin.

Under downward loading, one region of the purlin cross-section may be in compression while another is in tension. When the load direction reverses, these stress conditions can also reverse.

This behaviour matters when selecting aluminium profiles with asymmetric cross-sections or thin-walled elements that may have different resistance characteristics under opposite bending directions.

Wind uplift also places demands on the connections between the PV modules, purlins and primary structural members. Even when the aluminium profile has sufficient bending resistance, the complete system must be capable of transferring uplift forces through its fastening components.

The required design wind actions depend on project-specific factors such as geographical location, exposure, structural geometry and the applicable design standards. Local pressure variations within the array may also be important, particularly near exposed edges and corners.

Consequently, a support spacing that is suitable for one solar installation cannot automatically be transferred to another project with different wind conditions.

Snow Loads and Downward Bending

Snow load is an additional downward load that can affect the required strength and stiffness of aluminium solar purlins.

The magnitude and distribution of snow loads are a function of climatic conditions, module inclination, array geometry and applicable structural design requirements.

In places of heavy snowfalls, snow loading may be a significant factor in the maximum workable span between purlin supports.

Increasing the support spacing generally increases the bending moments and deflection for a given distributed load. The introduction of longer spans can make a previously acceptable profile no longer acceptable.

Snow distribution can be uneven too. Local accumulation or drifting, according to the mounting arrangement and site conditions, can result in loading patterns not the same as a uniformly distributed load.

These possibilities should be addressed with the appropriate design load cases, rather than assuming a uniform snow action over the structure.

For aluminium purlins the combination of bending resistance and serviceability is of special importance. A section may satisfy the strength requirements and still require additional stiffness to avoid excessive deformation.

Module Weight and Load Transfer Through Connections

The permanent load on the supporting structure is the self-weight of the photovoltaic modules. This load is generally more predictable than the wind or snow actions but the way it reaches the purlin depends on the mounting configuration.

Some systems transfer module loads through discrete clamps or fastening points rather than a perfectly uniform load along the entire length of the purlin.

This difference changes the distribution of the internal bending moment and shear force.

For instance, a purlin that supports multiple modules at discrete connection points may experience a series of point loads. The structural response obtained is dependent on the position of these forces relative to the supports.

The spacing of the module connections must therefore be distinguished from the spacing of the structural supports of the purlin.

Local forces can also be introduced by the locations of connections which require checking of the aluminium profile around bolt holes, channels or other fixing features.

Where applicable include the weight of the purlin itself and any associated fixing components.

Though the weight of a single component might be quite small, the cumulative weight can become considerable for large solar mounting structures.

Load Combinations and Structural Verification

Solar purlins are not designed for a single isolated loading case. They shall satisfy the appropriate requirements under the combinations of permanent, variable and environmental actions provided for the project.

Depending on the installation, different parts of the design may be governed by different combinations.

One condition may be governed by downward snow loading for bending or deflection and another may be governed by wind uplift for the resistance of certain connections. Local stability, support reactions or the bending-torsion interaction may affect other checks.

This implies that the most demanding load case for the aluminium purlin does not necessarily coincide with the most demanding case for its fasteners or supporting brackets .

Therefore, the design should consider the whole structural assembly rather than checking the purlin section only.

Applicable standards and project specifications define the load combinations, material resistance checks and serviceability criteria that need to be satisfied. For projects designed according to European standards, relevant provisions may include EN 1991 for actions on structures and EN 1999 for aluminium structures design including the relevant national requirements.

The final aluminium solar purlin span is ultimately a function of the interaction of the applied loads, cross-section properties, support conditions and connection performance.

Understanding these relationships is important for structural safety and material efficiency. Once the loading requirements are established, engineers can then weigh up whether a shorter support spacing with a lighter purlin or a longer span with a more substantial profile is the better solution for the whole solar mounting system.

Support Spacing vs. Material and Installation Efficiency

Selecting the appropriate support spacing for aluminium solar purlins is not only a structural engineering decision. It also influences material consumption, the number of supporting components, connection requirements and installation costs.

In large-scale solar projects, where similar structural arrangements are repeated across hundreds or thousands of module rows, relatively small design changes can have a considerable impact on the overall project budget.

The challenge is to find a balance between purlin span, aluminium profile weight and the total number of structural supports. A design that minimises the weight of individual purlins does not necessarily minimise the cost of the complete mounting system.

Shorter Support Spacing and Lighter Purlins

The span between supports is usually reduced which reduces bending moments and deflection for similar loading conditions. This may allow the engineers to consider profiles made of aluminium with a reduced cross-section or moment of inertia, provided that all structural requirements are satisfied.

A purlin supported at relatively short intervals might not need the same section depth as a comparable member spanning a much greater distance.

This can reduce the aluminium consumption per meter of purlin and may also simplify some of the handling and erection operations.

But closer support spacing usually requires more support points. Depending on the structural setup, this may mean more brackets, secondary beams, fastening components or other parts of the mounting system.

The other components add material and installation costs which need to be weighed against any savings from lighter purlins.

Therefore, a lighter purlin does not necessarily translate into a more economical solar mounting structure.

Longer Spans and Reduced Support Requirements

Increasing the spacing between supports can reduce the number of intermediate supports required along a purlin.

In some solar mounting configurations this could simplify the structural layout, reduce the number of connections and reduce the installation work associated with supporting components.

Fewer support points can also make for easier installation, especially where site access, positioning or installation time add to costs.

But longer spans place greater demands on the purlin structure.

To meet the bending resistance and deflection requirements it may be necessary for the engineers to select an aluminium profile with a greater section depth, a more efficient cross-sectional geometry or additional material.

The increase in profile weight could negate some or all of the savings from fewer supports.

Longer spans may also lead to greater support reactions or more demanding connection conditions, depending on the loading and structural configuration.

Therefore, the economic advantage of wider support spacing cannot be proven by the number of supports only.

Evaluating the Complete Mounting System

A good design will compare the total materials and installation requirements for different support arrangements, not just for a single component.

Another option might involve relatively light aluminium purlins supported at closer centers. Or another may use heavier profiles with fewer intermediate supports.

The two designs may meet the same structural performance requirements but could have very different overall costs.

In making the comparison, the aluminium weight of the purlins, number and cost of supporting members, connection components, fabrication requirements, transport and installation labour should all be considered.

Project specific factors can also affect outcome. Even a profile with a bit more material weight can be worthwhile if it simplifies manufacture or reduces the number of installation steps. In contrast, a light extrusion may not save much if it requires a much more complicated supporting arrangement.

This is particularly the case for utility scale photovoltaic projects where the mounting system is composed largely of repetitive structural elements.

Even a small reduction in material or assembly time per row of modules can add up to a significant amount over the entire installation.

Why the Most Efficient Span Is Not Always the Longest

To reduce the number of structural components it may be logical to maximise the support spacing. But the longest technically possible span is not always the most efficient choice.

As the spans increase the additional stiffness required to control deflection can lead to larger aluminium profiles. Beyond a certain point the savings from fewer supports may be outweighed by the extra material required for the purlins.

The opposite approach can also get inefficient. While very short spans may permit smaller purlin sections, the greater number of supporting elements can lead to a more costly and time-consuming overall installation.

Therefore, the best arrangement is the compromise between structural performance and total system requirements.

For aluminium solar purlin selection this means that support spacing and profile geometry must be considered together in the early design stages rather than selecting a profile first and then adapting the supports.

By examining a number of technically feasible configurations engineers can find ways to cut down on unnecessary aluminium use, make connections simpler and improve installation efficiency without sacrificing structural integrity.

Ultimately, the most economical support spacing is the one that provides the required structural performance at the lowest practical total system cost—not simply the one that uses the lightest purlin or the fewest supports.

Common Mistakes When Selecting Aluminium Solar Purlins

The support spacing is one of the most influential parameters in aluminium solar purlin design, but is sometimes treated as a fixed installation dimension rather than a variable that directly influences structural performance. This may lead to wrong profile selection , over deformation, unnecessary material consumption or connection problems that only arise after installation.

Many of these problems stem from the evaluation of individual components in isolation rather than considering the purlin, supports and PV modules as a complete structural system.

Selecting a Profile Without Verifying the Actual Span

Another common mistake is to select an aluminium purlin based on its size or based on its use in another solar project without checking the support spacing for the new project.

A profile that performs well over a 1,000 mm span cannot be automatically assumed to be suitable for a 1,500 mm span. Even when the loading conditions are similar, the increase in bending moment and deflection can be quite large.

This problem is more acute when a standard profile is used between projects, which have different structural layout, module arrangements or environmental conditions.

Manufacturers can provide aluminium profiles with similar outer dimensions but different wall thickness, internal geometries and mechanical properties. These differences can have a great influence on the bending resistance and stiffness.

For this reason the selection of aluminium purlins should start from the actual support arrangement and design loads and not from nominal profile dimensions or previous applications.

Focusing on Strength While Overlooking Deflection

Another common mistake is to check bending resistance without properly considering serviceability requirements.

A purlin may be strong enough to resist the applied loads but may be excessively deflected over the chosen span.

This is of particular importance for aluminium, since its modulus of elasticity is lower than that of structural steel. Even if an aluminium section has sufficient material strength, its stiffness may dictate the design.

Excessive deformation can affect the module’s alignment, connection behaviour and the mounting system’s intended geometry. Deflection limits are project specific and depend on structural design and requirements of the PV modules it supports.

Thus the bending resistance and the deflection have to be checked separately. Meeting one requirement does not mean that the other requirement has been met.

Assuming All Support Connections Behave the Same Way

The structural behaviour of a purlin depends both on the spacing of the supports and on the restraint offered by the supports.

A connection that allows rotation will not act the same as a connection that is designed to restrain rotation.

If the purlin is analysed as a continuous member with significant rotational restraint but the actual connections permit more movement, the calculated bending moments and deflections may not be representative of the installed structure.

Similarly, the presence of multiple supports does not ensure continuous-beam behaviour. Splices, connection details and installation conditions can affect how forces are transferred between adjacent spans.

Therefore, engineers are required to use support assumptions consistent with the actual connection design.

Ignoring Load Direction and Local Profile Behaviour

During their service life, solar mounting structures are subjected to different loading conditions. Wind uplift can cause the bending to reverse direction, while snow and permanent loads usually act downward.

The resistance of an aluminium profile can be different depending on the bending direction, in particular if the cross-section is not symmetric.

Thin-walled extrusions may also need checks for local buckling, torsion or concentrated forces around fastening points.

Neglecting such effects may lead to a profile which appears acceptable for a simplified bending calculation, but does not satisfy all the relevant structural requirements.

The connection between the purlin and its supports must also be able to transfer the calculated reactions, including uplift forces where applicable.

Optimising the Purlin Without Considering Total System Cost

The last mistake is to measure the efficiency of the material only with the weight of the aluminium purlin.

Although the selection of a lighter section may seem economical, if a much shorter spacing of supports is required, the additional members and fastening components may add to the total system cost.

Likewise, increasing the span and reducing the number of supports may require heavier or more complex aluminium extrusions.

So the most efficient arrangement is not always the one with the lowest profile weight or the greatest distance between supports.

It is the design which satisfies structural requirements and at the same time balances aluminium consumption, support quantities, connection details and installation effort.

These mistakes are especially important to avoid for utility-scale solar installations, because the same design decisions are repeated across large numbers of structural members.

Reducing design revisions, installation complications and unnecessary material use can be achieved with a systematic approach to support spacing, profile geometry, loading and connection verification.

The underlying principle is simple: select an aluminium solar purlin for the structural conditions under which it will actually be used, and not simply because its dimensions are similar to the dimensions of a previously used profile.

Choosing the Right Support Spacing for Aluminium Solar Purlins

There is no universal support spacing that will work for every aluminium solar purlin. The distance between supports should be selected according to the structural configuration, applied loads, geometry of the aluminium profile and the performance requirements of the solar mounting system.

A spacing layout that provides an efficient solution for one photovoltaic project may not work for another, especially if there are variations in wind exposure, snow loads, module dimensions or connection details.

Therefore, support spacing should be determined by structural evaluation rather than by simply choosing standard profile lengths or convenience of installation.

The selection process begins with understanding the real load path. Engineers must calculate how the forces from the photovoltaic modules are transmitted to the purlins and from there to the supporting structure. This includes determining the relevant load combinations, connection positions and support conditions .

When the values of these parameters are determined, various span arrangements can be tested against the required bending resistance, shear resistance, stiffness and stability criteria.

Deflection has special importance in aluminium structures. Aluminium has a lower elastic modulus than structural steel, thus a profile may need a larger second moment of area to be able to provide comparable stiffness under like conditions.

This doesn’t necessarily mean going to a heavier section. Aluminium extrusion allows for the modification of cross-sectional geometry, thus distributing material more efficiently. The bending performance can be improved by selecting an appropriate profile depth and wall configuration while keeping the material consumption to minimum.

However, the advantages of a particular geometry have to be verified against local buckling, connection requirements and relevant design standards.

Structural Verification and Project Requirements

Verify that the final support arrangement meets the structural design requirements for the project location.

For projects designed to European standards, EN 1999 (Eurocode 9) provides a framework for the structural design of aluminium, and the relevant parts of EN 1991 deal with structural actions such as wind and snow loads.

Also the applicable national provisions, project specifications and PV module manufacturer’s mounting requirements have to be taken into account.

These checks help to determine whether the selected purlin can safely transfer the expected loads, while maintaining acceptable deformation and connection performance.

Importantly, the assessment should reflect the actual structural layout. Different internal forces and deflections can be obtained from simply supported spans, continuous members and connections with varying degrees of rotational restraint.

Even if the calculations are done correctly, assumptions that do not represent the installed system can lead to an inappropriate selection.

Finding the Balance Between Performance and Cost

Once several technically suitable support arrangements have been identified, the next step is to compare their material and installation implications.

Shorter spans may permit lighter aluminium purlins but require more support points. Longer spans may reduce the number of supporting components while increasing the required purlin stiffness and bending resistance.

Neither approach is inherently more economical.

The most efficient solution depends on the total quantity of aluminium, the number and complexity of connections, fabrication requirements, transportation considerations and installation effort.

In utility-scale solar projects, this comparison becomes especially valuable because small differences in component weight or assembly time are repeated throughout the installation.

Rather than optimising each purlin independently, the objective should be to improve the efficiency of the complete solar mounting structure.

Conclusion: Support Spacing Is a Key Part of Aluminium Purlin Selection

The behaviour of aluminium solar purlins to bending, deflection and environmental loads is directly related to the support spacing. This also affects the profile geometry needed for sufficient structural performance and the overall material efficiency of the mounting system.

Increasing the distance between supports can reduce the number of structural connections, but may require a stiffer or stronger aluminium profile. The span can be reduced, thus reducing the load on each purlin but increasing the number of supports.

Thus, the right answer is not simply the smallest or the largest span possible. It is the arrangement which meets the structural requirements of the project and makes efficient use of the materials and installation resources.

For solar mounting manufacturers, EPC contractors and project engineers, an early assessment of aluminium purlin support spacing in the design process can help to avoid unnecessary material use, improve structural consistency and ease installation complications.

At IMG Group we understand the importance of matching the structural components to suit the technical requirements of each solar project. Careful coordination between component selection and structural design supports more efficient solar mounting solutions, from aluminium profile dimensions and cross-sectional properties to project specific material requirements.

Have a solar mounting project in mind? To discuss your aluminium profile and structural component requirements and see what supply options are available for your project contact IMG Group.